Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Evaluation of micro-energy dispersive X-ray fluorescence spectrometry for the analysis of plant materials

Texto completo
Autor(es):
Bueno Guerra, Marcelo Braga [1, 2] ; Schaefer, Carlos E. G. R. [1] ; de Carvalho, Gabriel G. A. [2] ; de Souza, Paulino F. [3, 2] ; Santos Junior, Dario [4] ; Nunes, Lidiane C. [2] ; Krug, Francisco J. [2]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Fed Vicosa, Dept Solos, BR-36570000 Vicosa, MG - Brazil
[2] Univ Sao Paulo, Res Support Ctr, Ctr Energia Nucl Agr, BR-13416000 Piracicaba, SP - Brazil
[3] Ctr Tecnol Canavieira, BR-13400970 Piracicaba, SP - Brazil
[4] Univ Fed Sao Paulo, Dept Ciencias Exatas & Terra, BR-09972270 Diadema, SP - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 28, n. 7, p. 1096-1101, 2013.
Citações Web of Science: 16
Resumo

An analytical procedure relying on micro-energy dispersive X-ray fluorescence spectrometry (mu-EDX) was evaluated for the quantitative determination of macro-, micronutrients and beneficial elements in pressed pellets of plant materials. For testing purposes, leaves from 23 varieties of sugar cane, previously analyzed by validated reference methods, based on wet decomposition procedures followed by ICP OES measurements were used. Linear correlations between analyte mass fractions in the tested samples and the corresponding mu-EDX intensities were obtained for P, K, Ca, S, Fe, Mn and Si with regression coefficients ranging from 0.9501 to 0.9933. Furthermore, the coefficients of variation of results in the 0.3 to 16% range (n = 3 sampling lines, 30 sampling sites per line), the spatial resolution of 50 mu m per site and the suitable detection limits for these analytes were additional features that demonstrated the performance of the proposed procedure as a useful tool for plant nutrient diagnosis. In addition, the results also indicate that mu-EDX can be recommended as a cross-validation method for analysis of plant materials, owing to its inherent non-destructive capability and, particularly, when dealing with analytes' micro-heterogeneity evaluation within the samples. (AU)

Processo FAPESP: 10/16379-0 - Estratégias de microamostragem para a análise de tecidos biológicos por espectrometria de emissão óptica com plasma induzido por laser
Beneficiário:Gabriel Gustinelli Arantes de Carvalho
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 10/17158-8 - Avaliação da espectrometria de emissão óptica com plasma induzido por laser (LIBS) para determinação de contaminantes inorgânicos em fertilizantes agrícolas
Beneficiário:Lidiane Cristina Nunes
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 12/16203-5 - Estratégias para análise direta de folhas de cana-de-açúcar por espectrometria de emissão óptica com plasma induzido por laser (LIBS)
Beneficiário:Marcelo Braga Bueno Guerra
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado