Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Evaluation of totally implantable catheters in healthy horses

Texto completo
Autor(es):
de Souza Garcia, Adriana Fernandes [1] ; Ribeiro, Gesiane [1] ; Arantes, Julia de Assis [2] ; Reginato, Gustavo Morandini [2] ; Xavier, Nathalia Villaca [2] ; Carregaro, Adriano Bonfim [2] ; Fernandes Silva, Thiago Jhonatha [2] ; Grigoletto, Renan [2] ; de Freitas, Silvio Henrique [2] ; Sampaio Doria, Renata Gebara [2]
Número total de Autores: 10
Afiliação do(s) autor(es):
[1] United Metropolitan Coll, Rua Minist Nelson Hungria 541, BR-05690050 Sao Paulo, SP - Brazil
[2] Univ Sao Paulo, Fac Anim Sci & Food Engn, Dept Vet Med, Rua Duque Caxias Norte 225, BR-13635900 Pirassununga, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: BMC Veterinary Research; v. 17, n. 1 OCT 26 2021.
Citações Web of Science: 0
Resumo

Background For horses requiring prolonged daily cephalic intravenous regional limb perfusion (IVRLP), the use of a totally implantable catheter (TIC) could be indicated to reduce complications associated with frequent venipuncture or external catheterization. This study aims to evaluate the implantation technique of the TIC in the cephalic vein of horses for IVRLP, describe the complications associated with the device's placement and use, and assess its viability up to 60 days after implantation. Totally implantable catheters, cut to 15 cm (n = 5) and 46 cm (n = 5) in length, were implanted into one cephalic vein in ten adult horses (n = 10). Twenty-four hours following placement, IVRLP with contrast was performed via the TIC and evaluated with radiography. Physical examinations, lameness evaluation, hematologic assessment, and the catheter patency tests were performed at scheduled intervals for the duration of catheterization (7-60 days). Results Catheters were implanted without difficulty and allowed for IVRLP 24 h post implantation. Complications resulted in removal of the catheters, with four maintained for 7 days, three in place for 15 days, and three catheters maintained for 60 days. Complications included lameness, limb swelling, catheter kinking, and venous thrombosis. Conclusions The implantation technique of the TIC in the cephalic vein of horses is feasible and requires minimal technical effort. Although TIC allows venous access without the need for repeated venipuncture, its long-term use presents complications. For horses requiring prolonged daily cephalic IVRLP, the use of a TIC could be indicated. However, the high incidence of venous thrombosis may limit clinical application. (AU)

Processo FAPESP: 19/03193-0 - Resposta transitória de mediadores inflamatórios induzida por lipopolissacarídeo no sangue e líquido alantoideano de éguas gestantes.
Beneficiário:Renata Gebara Sampaio Dória
Linha de fomento: Auxílio à Pesquisa - Regular
Processo FAPESP: 15/21430-9 - Avaliação da viabilidade da utilização do cateter totalmente implantado em membros de equinos
Beneficiário:Renata Gebara Sampaio Dória
Linha de fomento: Auxílio à Pesquisa - Regular