3D-printed reduced graphene oxide/polylactic acid electrodes: A new prototyped platform for sensing and biosensing applications

Texto completo
Autor(es):
Silva, Vinicius A. O. P. [1] ; Fernandes-Junior, Wilson S. [1] ; Rocha, Diego P. [2] ; Stefano, Jessica S. [2] ; Munoz, Rodrigo A. A. [2] ; Bonacin, Juliano A. [3] ; Janegitz, Bruno C. [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Dept Nat Sci Math & Educ, BR-13600970 Araras, SP - Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38400902 Uberlandia, MG - Brazil
[3] Univ Estadual Campinas, Inst Chem, POB 6154, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: BIOSENSORS & BIOELECTRONICS; v. 170, DEC 15 2020.
Citações Web of Science: 1
Resumo

This work presents a novel procedure involving the sequential chemical treatment to generate reduced graphene oxide (rGO) within 3D-printed polylactic acid (PLA) electrodes and their potential applications for sensing and biosensing. A new configuration of a compact all-3D-printed electrochemical device containing the three electrodes is presented, in which the working electrode was treated to generate rGO within PLA (rGO-PLA) after treatment within NaBH4. The rGO-PLA electrodes presented a notable current increase for the redox probe ferrocene-methanol in comparison with the same surface treated by dimethylformamide immersion. Also, the electrochemical impedance spectroscopic data that presented the lowest resistance to electron transfer for the proposed electrode. The electrochemical experiments were in accordance with Raman spectra and surface roughness obtained by atomic force microscopy images. As proofs-of-concept, the rGO-PLA electrode was applied for serotonin determination in synthetic urine using differential-pulse voltammetry with a limit of detection of 0.032 mu mol L-1. Also, the second application involved the fabrication of a tyrosinase-based biosensor capable of determining catechol in natural water samples with a limit of detection of 0.26 mu mol L-1. Based on both applications, the 3D-printed rGO-PLA showed to be an excellent platform for sensing and biosensing purposes.comment (AU)

Processo FAPESP: 13/22127-2 - Desenvolvimento de novos materiais estratégicos para dispositivos analíticos integrados
Beneficiário:Lauro Tatsuo Kubota
Linha de fomento: Auxílio à Pesquisa - Temático
Processo FAPESP: 17/21097-3 - Interações abelha-agricultura: perspectivas para a utilização sustentável
Beneficiário:Osmar Malaspina
Linha de fomento: Auxílio à Pesquisa - Temático
Processo FAPESP: 17/23960-0 - Estudo de mecanismo de oxidação de água por catalisadores operando em pH=7 e sua incorporação em eletrodos impressos em 3D
Beneficiário:Juliano Alves Bonacin
Linha de fomento: Auxílio à Pesquisa - Regular
Processo FAPESP: 19/26953-0 - Sensores e biossensores eletroquímicos impressos em 3D utilizando filamento de grafeno para a detecção de compostos fenólicos
Beneficiário:Wilson da Silva Fernandes Junior
Linha de fomento: Bolsas no Brasil - Iniciação Científica