Influence of particle size distribution on the analysis of pellets of plant materials by laser-induced breakdown spectroscopy

Texto completo
Autor(es):
Arantes de Carvalho, Gabriel Gustinelli [1] ; Santos, Jr., Dario [2] ; Gomes, Marcos da Silva [1] ; Nunes, Lidiane Cristina [1] ; Bueno Guerra, Marcelo Braga [1] ; Krug, Francisco Jose [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Ctr Nucl Energy Agr, NAPTISA Res Support Ctr Technol & Innovat Sustain, BR-13416000 Piracicaba, SP - Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Exatas & Terra, BR-09972270 Diadema, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY; v. 105, n. SI, p. 130-135, MAR 1 2015.
Citações Web of Science: 18
Resumo

Pellets of sieved plant materials (150, 106, 75,53 and 20 pm sieve apertures) were prepared and analyzed by laser-induced breakdown spectroscopy (LIBS), and the results for Ca, K, Mg, P, B and Mn were discussed as a function of particle size distribution. This parameter is of key importance for appropriate test sample presentation in the form of pressed pellets for quantitative analysis by LIBS. Experiments were carried out with a Q-switched Nd:YAG laser at 1064 nm, and a spectrometer with Echelle optics and an intensified charge-coupled device. Results indicated that smaller particles yielded up to 50% emission signal intensities' enhancement and attained better measurements' precision (site-to-site variation). Moreover, matrix effects were reduced by analyzing pellets prepared from <75 mu m sieved fractions (mean particle size = 32 mu m; d(95) = 102 mu m) and by using a 50 J cm(-2) laser fluence (220 mJ per pulse; 750 mu m laser spot size). The preparation of pellets from laboratory samples with monomodal particle size distributions, where most particles were smaller than 100 mu m, was decisive for improving analyte micro-homogeneity within the test samples and for attaining lower coefficients of variation of measurements, typically lower than 10% (n = 10 sites per pellet; 20 laser pulses per site). (C) 2014 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 10/16379-0 - Estratégias de microamostragem para a análise de tecidos biológicos por espectrometria de emissão óptica com plasma induzido por laser
Beneficiário:Gabriel Gustinelli Arantes de Carvalho
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 10/17158-8 - Avaliação da espectrometria de emissão óptica com plasma induzido por laser (LIBS) para determinação de contaminantes inorgânicos em fertilizantes agrícolas
Beneficiário:Lidiane Cristina Nunes
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 12/16203-5 - Estratégias para análise direta de folhas de cana-de-açúcar por espectrometria de emissão óptica com plasma induzido por laser (LIBS)
Beneficiário:Marcelo Braga Bueno Guerra
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado