Advanced search
Start date
Betweenand


Influence of the implant inclination on the stress distribution in overdenture-retaining bar with vertical misfit

Full text
Author(s):
Conrado Reinoldes Caetano
Total Authors: 1
Document type: Master's Dissertation
Press: Piracicaba, SP.
Institution: Universidade Estadual de Campinas (UNICAMP). Faculdade de Odontologia de Piracicaba
Defense date:
Examining board members:
Rafael Leonardo Xediek Consani; João Neudenir Arioli Filho; Marcelo Ferraz Mesquita
Advisor: Rafael Leonardo Xediek Consani; Mateus Bertolini Fernandes dos Santos
Abstract

The aim of this study was evaluate the stress distribution in overdentures with a bar-clip retention system presenting different implant inclinations, vertical misfit, and framework materials. Three-dimensional models of a jaw, an overdenture retained by two implants and a bar-clip attachment were modeled using specific software (SolidWorks 2010) ... Note: The complete abstract is available with the full electronic document (AU)

FAPESP's process: 11/16463-4 - Influence of implants' inclination on the stress distribution of overdenture-retaining bar with vertical misfit
Grantee:Conrado Reinoldes Caetano
Support Opportunities: Scholarships in Brazil - Master