Rheological Characterization and Safety Evaluation... - BV FAPESP
Advanced search
Start date
Betweenand
(Reference retrieved automatically from Web of Science through information on FAPESP grant and its corresponding number as mentioned in the publication by the authors.)

Rheological Characterization and Safety Evaluation of Non-Ionic Lamellar Liquid Crystalline Systems Containing Retinyl Palmitate

Full text
Author(s):
Chorilli, Marius [1] ; Rigon, Roberta B. [1] ; Calixto, Giovana [1] ; Cartezani, Pedro M. F. [1] ; Ribeiro, Maria C. A. P. [2] ; Polacow, Maria L. O. [2] ; Cerri, Paulo Sergio [3] ; Sarmento, Victor H. V. [4] ; Scarpa, Maria Virginia [1]
Total Authors: 9
Affiliation:
[1] Sao Paulo State Univ, Sch Pharmaceut Sci, UNESP, Rodovia Araraquara Jau, Km 01, BR-14801902 Araraquara, SP - Brazil
[2] Univ Metodista Piracicaba, Fac Hlth Sci, Rodovia Acucar S-N, BR-13400911 Piracicaba, SP - Brazil
[3] Sao Paulo State Univ, UNESP, Fac Dent, Rua Humaita 1680, BR-14801903 Araraquara, SP - Brazil
[4] Univ Fed Sergipe, Dept Chem, Av Vereador Olimpio Grande S-N, Itabaiana 49500000, SE - Brazil
Total Affiliations: 4
Document type: Journal article
Source: JOURNAL OF BIOMEDICAL NANOTECHNOLOGY; v. 12, n. 2, p. 394-403, FEB 2016.
Web of Science Citations: 6
Abstract

Retinyl palmitate (RP) is widely used as a special interest ingredient in dermatological formulations to improve the elasticity of the skin and to reduce wrinkles by stimulating collagen synthesis. Nanotechnology-based drug delivery systems, such as liquid crystalline systems (LCSs), can modulate drug permeation into skin and improve the drug action. The effects of such systems on the skin, however, are not completely known. Possible undesirable effects of these formulations on the skin can be detected and interpreted by histopathology and histomorphometry. The objective of this study was to perform a rheological characterization to evaluate the safety of RP used in a lamellar LCS in vitro and in vivo. LCSs containing polyether functional siloxane as a surfactant, silicon glycol copolymer as an oil phase and water at ratios of 60:10:30 and 40:30:30, with (F-1v and F-2v, respectively) and without (F-1 and F-2 respectively) RP, were investigated. The rheological characterization was performed using steady shear rate sweep tests and dynamic frequency sweep tests carried out for up to 30 days for various storage temperature conditions (25 +/- 2 degrees C, 37 +/- 2 degrees C and 5 +/- 2 degrees C). Cytotoxic effects were evaluated using J-774 mouse macrophages as a cellular model system. The in vivo tests were conducted on rabbits that had areas of skin treated as follows for 15 days: C (Control); F-1; F-1v; F-2; and F-2v. Histomorphometric and histopathological techniques were used to estimate the thicknesses of the epidermis and stratum corneum and the numbers of fibroblasts and leukocytes in the papillary dermis. Mean values were compared by ANOVA, followed by the Tukey test (p < 0.05). The steady shear rate sweep and dynamic frequency sweep tests confirmed the high viscosity of the LCS and the typical pseudo-plastic characteristic of the lamellar system. The RP-unloaded LCS and the RP-loaded LCS did not produce cytotoxicity, nor did they provoke significant thickening of the epidermis and stratum corneum. The number of leukocytes in the treated areas did not change; however, the number of fibroblasts in the area treated with F-1v was higher than in the areas treated with the control and F-2. The histological analyses demonstrated that none of the formulations irritated the skin and that formulation F-1v significantly increased the number of fibroblasts in the dermis, which could result in an increase in the production of collagen. (AU)

FAPESP's process: 10/17037-6 - Evaluation of the potential of nanostructured systems stabilized with polyether functional siloxane for cutaneous administration of methotrexate
Grantee:Marlus Chorilli
Support Opportunities: Regular Research Grants