Advanced search
Start date
Betweenand

Sonothrombolysis by focused and modulated acoustic radiation force using double beam

Grant number: 11/10809-6
Support Opportunities:Scholarships in Brazil - Doctorate
Effective date (Start): September 01, 2011
Effective date (End): November 30, 2015
Field of knowledge:Engineering - Biomedical Engineering - Bioengineering
Principal Investigator:Antonio Adilton Oliveira Carneiro
Grantee:Hermes Arytto Salles Kamimura
Host Institution: Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto (FFCLRP). Universidade de São Paulo (USP). Ribeirão Preto , SP, Brazil
Associated research grant:05/56447-7 - Research through images from high field magnetic resonance aimed at studies in humans, AP.CINAPCE.TEM
Associated scholarship(s):13/08116-8 - Acoustic power delivery of the multi-frequency ultrasound excitation for the treatment of acute ischemic stroke and its thermal effects and efficiency with microbubbles, BE.EP.DR
News published in Agência FAPESP Newsletter about the scholarship:
More itemsLess items
Articles published in other media outlets ( ):
More itemsLess items
VEICULO: TITULO (DATA)
VEICULO: TITULO (DATA)

Scientific publications (7)
(References retrieved automatically from Web of Science and SciELO through information on FAPESP grants and their corresponding numbers as mentioned in the publications by the authors)
KAMIMURA, HERMES A. S.; WANG, SHUTAO; CHEN, HONG; WANG, QI; AURUP, CHRISTIAN; ACOSTA, CAMILO; CARNEIRO, ANTONIO A. O.; KONOFAGOU, ELISA E.. Focused ultrasound neuromodulation of cortical and subcortical brain structures using 1.9 MHz. Medical Physics, v. 43, n. 10, . (11/10809-6, 13/08116-8)
KAMIMURA, H. A. S.; WANG, S.; WU, S-Y; KARAKATSANI, M. E.; ACOSTA, C.; CARNEIRO, A. A. O.; KONOFAGOU, E. E.. Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening. Physics in Medicine and Biology, v. 60, n. 19, p. 7695-7712, . (11/10809-6, 13/08116-8)
NOGUEIRA-BARBOSA, MARCELLO H.; SALLES KAMIMURA, HERMES ARYTTO; BRAZ, GUILHERME; AGNOLLITTO, PAULO M.; OLIVEIRA CARNEIRO, ANTONIO ADILTON. Preliminary results of vibro-acoustography evaluation of bone surface and bone fracture. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, v. 7, n. 5, p. 549-554, . (11/10809-6)
KAMIMURA, HERMES A. S.; PAVAN, THEO Z.; CARNEIRO, ANTONIO A. O.; PINTO, PEDRO T. C.; NETO, OCTAVIO M. P.; IEEE. Nonlinear mixing of two ultrasonic beams for transcranial sonothrombolysis. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), v. N/A, p. 3-pg., . (11/10809-6)
HERMES A.S. KAMIMURA; LIAO WANG; ANTONIO A.O. CARNEIRO; RANDALL R. KINNICK; KAI-NAN AN; MOSTAFA FATEMI. Vibroacoustography for the assessment of total hip arthroplasty. Clinics, v. 68, n. 4, p. 463-468, . (11/10809-6)
BAGGIO, ANDRE L.; KAMIMURA, HERMES A. S.; HENRIQUE LOPES, J.; CARNEIRO, ADILTON A. O.; SILVA, GLAUBER T.. Parametric array signal in confocal vibro-acoustography. APPLIED ACOUSTICS, v. 126, p. 143-148, . (11/10809-6)
DE MEDEIROS, L. J.; KAMIMURA, H. A. S.; ALTAFIM, R. A. P.; CARNEIRO, A. A. O.; AMORIM, M. F.; ALTAFIM, R. A. C.. Piezoelectret-based hydrophone: an alternative device for vibro-acoustography. MEASUREMENT SCIENCE & TECHNOLOGY, v. 26, n. 9, . (11/10809-6)
Academic Publications
(References retrieved automatically from State of São Paulo Research Institutions)
KAMIMURA, Hermes Arytto Salles. Multifrequency excitation and safety for transcranial sonothrombolysis. 2016. Doctoral Thesis - Universidade de São Paulo (USP). Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto (PCARP/BC) Ribeirão Preto.

Please report errors in scientific publications list using this form.

Filed patent(s) as a result of this research project

DISPOSITIVO AVALIADOR DE TRANSDUTORES BR1020160219515 - Universidade de São Paulo (USP) . Antonio Adilton Oliveira Carneiro ; Hermes Arytto Salles Kamimura ; Rogério Bulha Siqueira ; Danilo Januario Camara ; Thiago Wellington Joazeiro De Almeid - September 2016, 23